Kirkeby inverse filter
§The Kirkeby inverse filter is computed inverting the measured IR
1) The IR to be inverted is FFT transformed to frequency domain:
 H(f) = FFT [h(f)]
2) The computation of the inverse filter is done in frequency domain:
 
Where e(f) is a small,
frequency-dependent
regularization parameter
3) Finally, an IFFT brings back the inverse filter to time domain:
 c(t) = IFFT [C(f)]
Frequency-dependent regularization parameter
Inverse filter