Noise and vibration control in multiplex cinemas
  • A. Farina1; P. Fausti2


  • 1 Department of Industrial Engineering,
  •   University of Parma, Italy
  • 2 Department of Engineering,
  •   University of Ferrara, Italy
2
Topics
  • Design and realization of a new multiplex cinema in Genoa
  • Severe environamental conditions (industrial and trainway noise and vibrations, close to airport and docks)
  • Strict specification in terms of acoustical and vibration control set by the customer
3
Overview
4
Overview
5
Plan
6
Detailed Plan
7
Significant Numbers
  • 5 floors: 2 parking, 1 commercial, 1 cinema, 1 technical
  • 14 cinema rooms, 4980 m2
  • 1 x 499 seats, 6x216 seats, 5x143 seats, 2x322 seats = 3154 total seats
  • Entrance and services 2838 m2
  • Shops and restaurants: 9500 m2
  • 18800 m2 parking area (2 floors), 720 cars
8
Acoustical specifications (UCI)
  • External walls   R’w = 55 dB
  • Internal walls   R’w = 50 dB
  • Fire-resistant walls R’w = 55 dB
  • Wall between cinema rooms  R’w = 65 dB
  • Roof  R’w = 50 dB
  • Floor R’w = 60 dB
  • Internal doors    R’w = 45 dB
  • Wall of the projection room R’w = 50 dB
9
Acoustical specif. (Italian Law)
  • External walls   R’w = 42 dB
  • Internal walls   R’w = 50 dB
  • Fire-resistant walls R’w = 50 dB
  • Wall between cinema rooms  R’w = 50 dB
  • Roof  R’w = 42 dB
  • Floor R’w = 50 dB
  • Internal doors    ---
  • Wall of the projection room ---
10
Background noise
  • UCI requires that the Maximum SPL with Slow time constant complies with NR-30 curve (Lmax,slow < NR30) – this includes any source of noise, including passage of trains or aircrafts
  • The Italian Law requires that the noise produced by steady-state equipment (HVAC) has an A-weighted equivalent level less than 35 dB(A) (LA,eq < 35 dBA)
  • The UCI requirements are much more stringent than the Italian Law


11
Vibration limits
  • UCI requires that continuous vibrations are less than the curve 1 of BS-6472 (1992)
  • UCI requires also that the vibrations are less than the maximum allowed for building of category 5 in DIN-4150-2
  • In practice, the Italian standard UNI-9614 was applied, which specifies a maximum weighted acceleration level of 71 dB
12
Technical details
13
Technical details
14
Technical details
15
Technical details
16
Vibration control
17
Preliminary measurements
18
Preliminary measurements (vibrations)
19
Realization
20
Final verification measurements
21
Final verification measurements
22
Vibration measurements
23
Vibration measurements
24
Vibration measurements
25
Vibration measurements
26
Conclusions
  • Almost all noise and vibrations specifications were fulfilled
  • The rubber support of horizontal structures was able to decouple vibrations above 5 Hz
  • The multilayer walls employing triple gypsum boards gave sound insulation much higher than expected
  • Proper soundproofing was required for reducing the HVAC noise below the NR-30 curve