Methods
nThree kinds of tests are employed:
1.Sound System è Binaural microphone
2.Mouth simulator è Hands-free microphone
3.Mouth simulator è Binaural microphone
nIn cases 2 and 3, a mouth simulator compliant with ITU-T Recommendation P51 is required
n
nThe test signal must be pre-processed, for shaping its spectrum in compliance with the standardized emission of the human talker (male or female)