| Page 24
18.05.2006 Angelo Farina
UNIPR / ASK Industries | All Rights Reserved | Confidential
Equalization of the whole system
§The inverse filter can be either pre-convolved with the test signal or post-convolved with the result of the measurement §Pre-convolution usually reduces the SPL being generated by the loudspeaker, resulting in worst S/N ratio §On the other hand, post-convolution can make the background noise to become “coloured”, and hence more perciptible §The resulting anechoic IR becomes almost perfectly a Dirac’s Delta function: